<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15077</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: trailing edge clamps already on actuator,   possible sensor or software error.
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
If no clamp is on the TEC actuator, check for faulty magnet sensor by using "tec" command. If it is
faulty, use "set al ms 0" to bypass the sensor and get the customer going. Arrange for field service.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Select RESUME and see if it works. If not, call Creo service.
</text></DescriptionText>
</OperatorAction>
<Cause>
Faulty TEC magnet sensor
</Cause>
<Cause>
Firmware bug
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_ms.xml</LinkAddress><LinkTitle>NVS: al ms</LinkTitle></Link>
<Link><LinkAddress>../commands/tec.xml</LinkAddress><LinkTitle>Command: tec</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:51 2008 PST
</Updated>
<Links>
</Links>
</Error>